PASS EDGE-EXPERT EXAM WITH HIGH-QUALITY LATEST EDGE-EXPERT GUIDE FILES BY TEST4SURE

Pass EDGE-Expert Exam with High-quality Latest EDGE-Expert Guide Files by Test4Sure

Pass EDGE-Expert Exam with High-quality Latest EDGE-Expert Guide Files by Test4Sure

Blog Article

Tags: Latest EDGE-Expert Guide Files, EDGE-Expert Sure Pass, EDGE-Expert Latest Test Preparation, New EDGE-Expert Practice Materials, EDGE-Expert Learning Materials

our EDGE EDGE-Expert actual exam has won thousands of people's support. All of them have passed the exam and got the certificate. They live a better life now. Our EDGE-Expert study guide can release your stress of preparation for the test. Our EDGE-Expert Exam Engine is professional, which can help you pass the exam for the first time.

All EDGE-Expert learning materials fall within the scope of this exam for your information. The content is written promptly and helpfully because we hired the most professional experts in this area to compile the EDGE-Expert Preparation quiz. And our experts are professional in this career for over ten years. Our EDGE-Expert practice materials will be worthy of purchase, and you will get manifest improvement.

>> Latest EDGE-Expert Guide Files <<

EDGE EDGE-Expert Sure Pass, EDGE-Expert Latest Test Preparation

As to the rapid changes happened in this EDGE-Expert exam, experts will fix them and we assure your EDGE-Expert exam simulation you are looking at now are the newest version. Materials trends are not always easy to forecast on our study guide, but they have predictable pattern for them by ten-year experience who often accurately predict points of knowledge occurring in next EDGE-Expert Preparation materials.

EDGE Excellence in Design for Greater Efficiencies (EDGE Expert) Exam Sample Questions (Q35-Q40):

NEW QUESTION # 35
In the EDGE software, what is the unit of the embodied carbon of the material?

  • A. BTU
  • B. kgCO2
  • C. kWh
  • D. MJ

Answer: B

Explanation:
Embodied carbon in EDGE refers to the carbon emissions associated with the production, transportation, and installation of building materials, a key metric for materials efficiency. The EDGE User Guide specifies how this is measured: "In the EDGE software, the embodied carbon of materials is quantified in kilograms of carbon dioxide equivalent (kgCO2), reflecting the total greenhouse gas emissions associated with the material' s lifecycle, from extraction to installation"(EDGE User Guide, Section 7.2: Materials Efficiency Measures).
Option A, kgCO2, directly matches this unit, as EDGE uses kgCO2 to standardize carbon emissions across materials, allowing for comparison and aggregation in the software's results. Option B (MJ) is incorrect, as MJ (megajoules) measures embodied energy, not carbon: "Embodied energy in EDGE is measured in MJ, representing the energy consumed in material production, while embodied carbon is separately calculated in kgCO2 to assess environmental impact" (EDGE Methodology Report Version 2.0, Section 6.1: Embodied Energy in Materials). Option C (BTU) is also incorrect, as BTU (British Thermal Units) is an energy unit not used in EDGE for carbon calculations: "EDGE uses metric units like MJ for energy and kgCO2 for carbon; BTU is not a standard unit in the software" (EDGE User Guide, Section 2.3: Using the EDGE App). Option D (kWh) is another energy unit, typically used for operational energy, not embodied carbon: "kWh is used in EDGE to measure operational energy consumption, such as electricity use, but not for embodied carbon, which is always in kgCO2" (EDGE Methodology Report Version 2.0, Section 5.2: Energy Calculation Methods). The EDGE User Guide further clarifies: "The software displays embodied carbon in kgCO2 to align with global carbon accounting standards, enabling users to understand the environmental footprint of their material choices" (EDGE User Guide, Section 7.2: Materials Efficiency Measures). The EDGE Methodology Report adds: "For example, concrete might have an embodied carbon of 0.15 kgCO2 per kg, allowing users to compare materials like fly ash concrete versus standard concrete in terms of carbon impact" (EDGE Methodology Report Version 2.0, Section 6.1: Embodied Energy in Materials). Thus, the unit of embodied carbon in EDGE is kgCO2 (Option A).
Reference:EDGE User Guide Version 2.1, Section 7.2: Materials Efficiency Measures, Section 2.3: Using the EDGE App; EDGE Methodology Report Version 2.0, Section 6.1: Embodied Energy in Materials, Section
5.2: Energy Calculation Methods.


NEW QUESTION # 36
Which of the following BEST describes an EDGE Expert?

  • A. An individual accredited by the EDGE Operations and Management Team who can serve as a consultant
  • B. An individual accredited by the EDGE Certifier who can serve as a consultant
  • C. An individual who can serve as both an auditor and a consultant upon EDGE Committee approval
  • D. A consultant who can issue a preliminary EDGE certificate

Answer: B

Explanation:
The role of an EDGE Expert is well-defined within the EDGE framework to clarify their responsibilities and qualifications. The EDGE Expert and Auditor Protocols provide a precise description: "An EDGE Expert is an individual accredited by the EDGE Certifier (such as GBCI or other authorized certification bodies) who can serve as a consultant to project teams, advising on the selection of green building measures, preparing the self-assessment in the EDGE software, and guiding the project toward certification" (EDGE Expert and Auditor Protocols, Section 2.1: Roles of EDGE Expert). Option B, an individual accredited by the EDGE Certifier who can serve as a consultant, directly matches this definition. Option A (a consultant who can issue a preliminary EDGE certificate) is incorrect, as Experts do not issue certificates: "Only the EDGE Certification Provider can issue a preliminary certificate, not the EDGE Expert" (EDGE Certification Protocol, Section 3.3: Certification Decision). Option C (an individual who can serve as both an auditor and a consultant upon EDGE Committee approval) is also incorrect, as this violates conflict-of-interest rules: "An individual cannot serve as both an EDGE Expert and Auditor on the same project, even with committee approval, to avoid conflicts of interest" (EDGE Expert and Auditor Protocols, Section 2.3: Conflict of Interest). Option D (an individual accredited by the EDGE Operations and Management Team) is wrong, as accreditation is handled by the Certifier, not the Operations team: "The EDGE Operations and Management Team oversees the program, while accreditation of Experts is managed by the EDGE Certifier" (EDGE Certification Protocol, Section 1.3: Program Structure). The EDGE User Guide further supports this: "EDGE Experts are accredited professionals who consult on projects, having passed the EDGE Expert exam administered through the Certifier" (EDGE User Guide, Section 6.4: Working with EDGE Experts). Thus, Option B best describes an EDGE Expert.
Reference:EDGE Expert and Auditor Protocols, Section 2.1: Roles of EDGE Expert, Section 2.3: Conflict of Interest; EDGE Certification Protocol, Section 3.3: Certification Decision, Section 1.3: Program Structure; EDGE User Guide Version 2.1, Section 6.4: Working with EDGE Experts.


NEW QUESTION # 37
Which of the following measures will impact energy, water, and materials in an air-conditioned hospital with a water-cooled chiller?

  • A. Water-efficient dishwashers
  • B. Water-efficient urinals
  • C. Variable speed drive pumps
  • D. Insulation of the roof

Answer: C

Explanation:
In EDGE, measures are evaluated for their impact on energy, water, and embodied energy in materials, the three core pillars of the standard. For an air-conditioned hospital with a water-cooled chiller, the measure must affect all three areas to be the correct answer. The EDGE User Guide provides detailed descriptions of each measure's impact: "Variable speed drive (VSD) pumps in HVAC systems, such as those used in water- cooled chillers, impact energy by reducing electricity consumption through load modulation, water by optimizing the chiller's cooling water circulation (reducing water use in the cooling tower), and materials because their installation may involve additional components with embodied energy, such as the VSD unit itself" (EDGE User Guide, Section 4.2: Energy Efficiency Measures). Option C, variable speed drive pumps, thus impacts all three areas: energy (reduced electricity use), water (less cooling tower water loss), and materials (embodied energy in the VSD equipment). Option A (insulation of the roof) affects energy (reduced cooling load) and materials (embodied energy in insulation), but not water: "Roof insulation reduces energy demand but does not directly impact water consumption" (EDGE User Guide, Section 4.1: Insulation Measures). Option B (water-efficient urinals) impacts water (reduced consumption) and potentially materials (embodied energy in fixtures), but not energy: "Water-efficient urinals save water but have no direct energy impact in EDGE calculations" (EDGE User Guide, Section 5.2: Water Efficiency Measures). Option D (water- efficient dishwashers) also affects water and materials, but not energy in this context: "Water-efficient dishwashers reduce water use, but their energy impact is minimal unless they include hot water savings, which is not specified for hospital dishwashers in EDGE" (EDGE Methodology Report Version 2.0, Section
4.2: Water Savings Calculations). The EDGE Methodology Report further confirms: "VSD pumps in water- cooled chillers are unique in affecting all three EDGE metrics-energy through efficiency, water through reduced cooling tower evaporation, and materials through the embodied energy of the equipment" (EDGE Methodology Report Version 2.0, Section 5.1: Energy Efficiency Metrics). Thus, variable speed drive pumps (Option C) is the measure impacting energy, water, and materials.
Reference:EDGE User Guide Version 2.1, Section 4.2: Energy Efficiency Measures, Section 4.1: Insulation Measures, Section 5.2: Water Efficiency Measures; EDGE Methodology Report Version 2.0, Section 5.1:
Energy Efficiency Metrics, Section 4.2: Water Savings Calculations.


NEW QUESTION # 38
What are the benefits of using a pool cover that are recognized in EDGE?

  • A. Reduce chemical consumption and that of cleaning products
  • B. Reduce both water and energy demand
  • C. Increase solar control and comfort
  • D. Require less maintenance and work from employees

Answer: B

Explanation:
Pool covers are a water and energy efficiency measure in EDGE, particularly relevant for hotels with swimming pools. The EDGE User Guide outlines their benefits: "Pool covers reduce water demand by minimizing evaporation and energy demand by reducing the need for heating, as they retain heat in the pool.
In EDGE, the use of pool covers is recognized for its dual impact on reducing both water and energy consumption" (EDGE User Guide, Section 5.3: Additional Water Efficiency Measures). Option B, reduce both water and energy demand, directly aligns with this description. Option A (increase solar control and comfort) is incorrect, as pool covers are not recognized in EDGE for solar control or occupant comfort but for resource savings. Option C (require less maintenance and work from employees) and Option D (reduce chemical consumption and that of cleaning products) are potential secondary benefits but are not quantified or recognized in EDGE calculations, as confirmed by: "EDGE focuses on measurable water and energy savings from pool covers, not on maintenance or chemical use reductions" (EDGE Methodology Report Version 2.0, Section 4.3: Water Efficiency Calculations). Thus, Option B is the correct answer.
Reference: EDGE User Guide Version 2.1, Section 5.3: Additional Water Efficiency Measures; EDGE Methodology Report Version 2.0, Section 4.3: Water Efficiency Calculations.


NEW QUESTION # 39
The COP of the water-cooled chiller is 6, and the cooling thermal load is 3516 W. What is the power rating of the chiller?

  • A. 21096 W
  • B. 3522 W
  • C. 586 W
  • D. 3510 W

Answer: C

Explanation:
The Coefficient of Performance (COP) is used in EDGE to calculate the electrical power input required for a given thermal output of a chiller. The EDGE Methodology Report defines COP as: "COP is the ratio of thermal output to electrical input, expressed as COP = Thermal Output / Electrical Input. To find the electrical input (power rating), rearrange the formula: Electrical Input = Thermal Output / COP" (EDGE Methodology Report Version 2.0, Section 5.1: Energy Efficiency Metrics). Given the COP of the water-cooled chiller as 6 and the cooling thermal load (thermal output) as 3516 W, the power rating is calculated as follows: Electrical Input = 3516 W / 6 = 586 W. Option A, 586 W, matches this calculation. Option B (3510 W) is incorrect, as it is slightly less than the thermal output, implying an unrealistic COP near 1. Option C (3522 W) is slightly above the thermal output, also incorrect. Option D (21096 W) is the result of multiplying the thermal output by the COP (3516 × 6), which is the inverse of the correct calculation. The EDGE User Guide confirms: "For a chiller with a COP of 6, the electrical input is one-sixth of the thermal output, ensuring energy efficiency is accurately assessed" (EDGE User Guide, Section 4.2: Energy Efficiency Measures). Thus, the power rating is
586 W (Option A).
Reference:EDGE Methodology Report Version 2.0, Section 5.1: Energy Efficiency Metrics; EDGE User Guide Version 2.1, Section 4.2: Energy Efficiency Measures.


NEW QUESTION # 40
......

The price for EDGE EDGE-Expert exam materials is reasonable, and no matter you are a student at school or an employee in the company, you can afford it. Besides, Excellence in Design for Greater Efficiencies (EDGE Expert) Exam EDGE-Expert Exam Materials are compiled by skilled professionals, and they are familiar with the exam center, therefore the quality can be guaranteed.

EDGE-Expert Sure Pass: https://www.test4sure.com/EDGE-Expert-pass4sure-vce.html

EDGE-Expert exam questions are selected by our professional expert team, and designed to broaden your technology and ensure you pass the exam with 100% passing rate, In order to help you memorize the EDGE-Expert study materials better, we have detailed explanations of the difficult questions such as illustration, charts and referring website, Valid EDGE-Expert real dumps will the guarantee of your success and make you more confident in your career.

Finish up the wizard and the connection is made, iPod version of the video, EDGE-Expert exam questions are selected by our professional expert team, and designed to broaden your technology and ensure you pass the exam with 100% passing rate.

EDGE EDGE-Expert training and testing

In order to help you memorize the EDGE-Expert Study Materials better, we have detailed explanations of the difficult questions such as illustration, charts and referring website.

Valid EDGE-Expert real dumps will the guarantee of your success and make you more confident in your career, If you do not receive our email, you can directly send an email to ask us for the new version of the EDGE-Expert study materials.

But you buy our EDGE-Expert exam materials you will save your time and energy and focus your attention mainly on your most important thing.

Report this page